Silica dust air monitoring & RPE fit-testing, explained
Engineered stone and other silica-containing materials put respirable crystalline silica (RCS) exposure under some of the strictest WHS scrutiny in construction right now. Here's what triggers monitoring, and why a one-off test isn't the end of the obligation.
This page is general information only, based on publicly available sources as at the date this page was last reviewed (see the sources listed further down this page for that date). It is not legal, compliance, or insurance advice, is not exhaustive, and may not reflect the most current requirements -- regulations, licensing rules, and insurance thresholds change, and requirements can vary by project, site, and contract. Always verify current requirements directly with the relevant state or territory regulator, your insurer, or a qualified advisor before relying on anything here.
The short answer
SafeWork NSW requires air monitoring for respirable crystalline silica when there's genuine uncertainty about whether exposure exceeds the workplace exposure standard (0.05 mg/m³ over 8 hours), and separately requires regular health monitoring — including RPE fit-testing — for workers carrying out ongoing, significant-risk silica processing work. Engineered stone specifically has been subject to its own escalating restrictions in recent years.
Silica rules — especially around engineered stone — have changed rapidly and vary by state. Treat this as a starting point, not a final answer, and confirm the current position with your own state or territory WHS regulator before relying on it, particularly for anything involving engineered stone.
Air monitoring, health monitoring, and RPE fit-testing
These are three separate obligations, not one. Air monitoring measures airborne silica in a worker's breathing zone for the duration of their shift, and results typically need to be kept and shared with the worker. Health monitoring tracks an individual worker's health over time once they're doing ongoing, significant-risk silica work — SafeWork NSW's guidance also ties this to registration on a Silica Worker Register within a set period of starting high-risk processing. RPE fit-testing is its own requirement on top of both: workers given tight-fitting respiratory protection need to be fit-tested when they start, and then on a recurring basis after that.
Why this isn't a one-off check
An RPE fit-test doesn't cover a different mask model or a worker who's changed facial hair, and air monitoring from one job doesn't establish exposure on a different one with different materials, tools, or ventilation. Treating either as a single document to file away misses that the obligation is tied to the actual work being done, not a date on a certificate — a new high-risk process starting, a change in materials or controls, or simply the recurring interval a company's own risk assessment sets can all trigger a fresh monitoring event.
What ComplySite tracks instead
Each monitoring event or fit-test is logged against the subcontractor and the specific process it covers, with no due date forced onto something that's genuinely event-driven rather than calendar-driven — it only asks for a new entry when the work itself says one's needed, and keeps the full log, not just the latest result, for an audit-ready export. A subcontractor can log an event from their phone on site through the same no-login link used for document uploads, even without signal — it syncs automatically once they're back online.
Another event-driven item: trench shoring
Silica monitoring isn't the only compliance item that opens with an event and stays open until someone closes it out. A trench or excavation requiring shoring works the same way — it's not a document that expires, and it's not a fixed-schedule inspection either; it's opened the moment the trench is dug and needs periodic re-checking until it's explicitly backfilled or otherwise closed out. ComplySite tracks items like this — open, periodically re-checked, then explicitly closed — the same way, showing "Open since [date]" until someone on the project marks it finished.
Check the current position directly
- Safe Work Australia
National WHS policy body — publishes the model crystalline silica code of practice
- SafeWork NSW — Crystalline silica & engineered stone
Source for the air/health monitoring and RPE fit-testing details above — example state regulator, confirm with your own state's
This page was last reviewed against those sources on 12 November 2026. See the full sources list for every state and territory regulator.
Frequently asked questions
Is air monitoring required for every job involving concrete or stone?
No -- SafeWork NSW requires air monitoring when there's genuine uncertainty about whether exposure exceeds the workplace exposure standard (0.05 mg/m³ over 8 hours) for the process being done. Routine low-risk work may not trigger it, but don't assume without checking the specific process against current guidance.
What's the difference between air monitoring and health monitoring?
Air monitoring measures airborne silica levels at the worksite, done in the worker's breathing zone for the duration of their shift. Health monitoring tracks an individual worker's health over time -- including RPE fit-testing -- and is required once a worker is doing ongoing, significant-risk silica work, separate from any single air monitoring result.
Does engineered stone have its own rules?
Yes, and they've changed significantly and quickly in recent years, including processing restrictions and a notification requirement before doing repair or modification work on legacy engineered stone installed before the relevant ban. This is the area most likely to be out of date in any general guidance, including this page -- check the current position with your state regulator before relying on older information.
Who can carry out air monitoring?
SafeWork NSW requires air monitoring to be conducted by a suitably qualified person. A builder shouldn't rely on an informal assessment or a subcontractor's own judgement call for what's meant to be a genuine compliance record.
Can a subcontractor log a monitoring event without a ComplySite account?
Yes. The same no-login link used for document uploads also covers logging a monitoring event or fit-test, straight from a phone on site -- including when there's no signal, with the entry syncing automatically once the connection comes back.